Main switch trips when the air conditioning comes on
We check whether the trip is due to an overload on the main switch or to the compressor starting, and solve it with a dedicated circuit for the air conditioning and the right protection.
We work in the town centre, the urbanisations and the industrial units of Las Torres de Cotillas, in the heart of the Vega Media del Segura. We fix faults, renew old installations and leave every home with its paperwork in order.

Around Murcia
Las Torres de Cotillas lies in the Vega Media del Segura, next to Molina de Segura and Alguazas and a short distance from Alcantarilla, with the river and the huerta on one side and hills with villa urbanisations on the other. It is a municipality that has grown a great deal: blocks of flats, neighbourhoods of terraced houses and an industrial area with food, transport and workshop units have been added to the traditional core of village houses.
That growth shows in the electrical installation. Many homes were extended in stages, adding a floor, a kitchen or a garage without redoing the consumer unit, and still run on protection designed for the original house. In flats from the eighties and nineties, the most common complaint is that the main switch trips as soon as the air conditioning, hob and oven run together; in the newer terraced houses, the usual requests are for improvements: a charging point, solar panels, garden lighting or motorised shutters.
In the huerta houses near the river and on the hillside plots, damp and outdoor lines are the main source of faults: cables to the pump or the pool buried without protection, garden lights with water inside and earth connections that dry out in summer and lose effectiveness. In the industrial units, emergencies usually come from lost phases, burnt-out contactors and boards that overheat when working at full load.
Cases and jobs
The faults and jobs we come across most here. Each one links to its service.
We check whether the trip is due to an overload on the main switch or to the compressor starting, and solve it with a dedicated circuit for the air conditioning and the right protection.
When the home grew with a new floor or garage, the board was left too small. We fit one with room for all the circuits, RCDs by group and surge protection.
We use the building work to redo circuits, add sockets where they are needed and leave the bathroom with its safety zones according to ITC-BT-27, with each appliance at the correct distance from the shower or bath.
We check the switch, the supply and the tubular motor, replace the damaged switch or motor and leave the limit switches adjusted.
An insulation fault in the inverter or its line can affect the rest of the home. We isolate the photovoltaic installation, locate the fault and get the power back to the rest of the house.
We disconnect the outdoor line, dry or replace the light and its connection box, and measure the cable insulation before switching the garden back on.
We replace the damaged contactor or thermal overload relay, check the motor and its line and leave the machine running with protection matched to its consumption.
We repair the garage lighting circuit, replace faulty sensors and light fittings, and check that the emergency lighting works on ramps and at exits.
We run a new line from the consumer unit to the parking space, install the wallbox with its protection and set it to the contracted power.
When an independent dwelling is created out of a house, it needs its own certificate to get a supply. We check the installation, issue the CIE and register it so you can take out a contract.
We mount the fan on a fixing that will hold its weight, connect it with its controller and leave the light and speeds working separately.
The town centre is full of two-storey houses refurbished bit by bit. They usually have the consumer unit by the entrance, with a single RCD, and circuits that mix the ground floor with the upper floor. Splitting them by floor and by use already solves a good share of the trips.
In the blocks and terraced houses from the eighties and nineties the installation is more orderly, but with cable sizes and power levels from another era. And in the hillside villas the weak point is outside: pool, irrigation, gate and garden lighting, with long lines exposed to sun and damp.
The resistance of an earth connection depends a great deal on the ground. On plots with dry, stony soil, a rod that gave a good reading in winter can fall short in the middle of August. If the earth is not working, a leaking appliance can give you a shock when you touch it, because the leakage current has no other path than through the person's body.
We measure the earth resistance with dedicated equipment, check the rod connection and the conductor running to the consumer unit and, if the reading is not good, add rods or improve the electrode until it is within what ITC-BT-18 sets out.
Services
Old installations with no earthing or two-wire circuits, kitchen and bathroom refits, shops, new-build villas, air conditioning lines and swimming pools.
Old fuse boxes swapped for a new unit, extra circuits, high-immunity RCDs, surge protection and moving the consumer unit to another wall.
RCD or breaker tripping with the oven, water heater, air conditioning or for no obvious reason: we test the insulation and eliminate the leak.
Wallbox at a villa, community garage space or business: dedicated line, ITC-BT-52 protection, power management and a certificate for the installation.
Loss of power to cold rooms, servers, machinery or the equipment you need to open, and UPS or generator failures: critical systems first.
Frequently asked questions
Yes. We work in the town centre, the villa urbanisations, the huerta and the industrial estates, and also in Alguazas, Lorquí, Ceutí and Molina de Segura. Tell us in the form the urbanisation or a landmark and the type of fault.
Because some equipment runs on its own: the water heater, the pool pump, the programmed irrigation, the fridge or the garage freezer. If one of them has a leak, the RCD cuts out even though nothing has been switched on by hand. To find it, we measure the insulation of each circuit and test the automatic equipment one by one.
If the extension creates an independent dwelling or changes the power significantly, yes, a new certificate is needed. For small extensions, such as a room with a couple of circuits, we check it during the visit and tell you which procedure applies, so that the consumer unit and the paperwork reflect what is really there.
Yes. We organise the work by area so you are not left without power in the whole home: we keep the fridge and a couple of sockets live, redo one room at a time and fit the new consumer unit at the end. We protect the furniture while we cut chases in the walls and fill them in when we finish.
That is the classic sign of a lost phase: single-phase equipment keeps working and three-phase equipment stops or hums. Switch off the affected machines so the motors do not overheat and let us know through the form. We measure voltages at the board and at the unit's incoming supply, locate the faulty fuse, terminal or cable and repair it; if the fault comes from the grid, we tell you how to report it to the distribution company.
Tell us what is happening, which village or urbanisation it is in and a phone number, and we will arrange the visit.